Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 54
Filtrar
1.
J Orthop Trauma ; 38(1): 42-48, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-37653607

RESUMO

OBJECTIVE: To quantify work impairment and economic losses due to lost employment, lost work time (absenteeism), and lost productivity while working (presenteeism) after a lateral compression pelvic ring fracture. Secondarily, productivity loss of patients treated with surgical fixation versus nonoperative management was compared. DESIGN: Secondary analysis of a prospective, multicenter trial. SETTING: Two level I academic trauma centers. PATIENT SELECTION CRITERIA: Adult patients with a lateral compression pelvic fracture (OTA/AO 61-B1/B2) with a complete posterior pelvic ring fracture and less than 10 mm of initial displacement. Excluded were patients who were not working or non-ambulatory before their pelvis fracture or who had a concomitant spinal cord injury. OUTCOME MEASURES AND COMPARISONS: Work impairment, including hours lost to unemployment, absenteeism, and presenteeism, measured by Work Productivity and Activity Impairment assessments in the year after injury. Results after non-operative and operative treatment were compared. RESULTS: Of the 64 included patients, forty-seven percent (30/64) were treated with surgical fixation, and 53% (30/64) with nonoperative management. 63% returned to work within 1 year of injury. Workers lost an average of 67% of a 2080-hour average work year, corresponding with $56,276 in lost economic productivity. Of the 1395 total hours lost, 87% was due to unemployment, 3% to absenteeism, and 10% to presenteeism. Surgical fixation was associated with 27% fewer lost hours (1155 vs. 1583, P = 0.005) and prevented $17,266 in average lost economic productivity per patient compared with nonoperative management. CONCLUSIONS: Lateral compression pelvic fractures are associated with a substantial economic impact on patients and society. Surgical fixation reduces work impairment and the corresponding economic burden. LEVEL OF EVIDENCE: Economic Level IV. See Instructions for Authors for a complete description of levels of evidence.


Assuntos
Fraturas Ósseas , Fraturas por Compressão , Ossos Pélvicos , Adulto , Humanos , Estudos Prospectivos , Fraturas Ósseas/complicações , Fraturas Ósseas/cirurgia , Ossos Pélvicos/lesões , Pelve , Emprego
2.
Injury ; 54(10): 110965, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37572509

RESUMO

OBJECTIVES: To identify deep infection risk factors in patients with open tibial shaft fractures and to develop a scoring algorithm to predict the baseline deep infection risk in this patient population. METHODS: A retrospective cohort study conducted at a single academic trauma center identified patients with open tibial shaft fractures treated with intramedullary nail fixation from December 2006 to October 2020. The primary outcome was a deep surgical site infection requiring surgical debridement. The outcome was identified by Current Procedural Terminology codes and confirmed with a medical chart review documenting evidence of a tibial draining wound or sinus tract. RESULTS: Deep surgical site infection occurred in 13% of patients (97/769). Factors that predicted deep surgical site infection were identified. Gustilo-Anderson type IIIB or IIIC was the strongest predictor with a 12-fold increase in the odds of deep infection (OR 11.8, p < 0.001). Additional factors included age >40 years (OR 1.7, p = 0.03), American Society of Anesthesiologists score ≥3 (OR 1.9, p < 0.01), Gustilo-Anderson type IIIA vs. type I or II (OR 2.8, p = 0.004), and gunshot wounds (OR 2.9, p = 0.02). The risk scoring model predicted patients who would develop an infection with an acceptable level of accuracy (AUC 0.79). The risk score categorized patients from a low probability of deep infection 2%-6% with <10 points to high risk (58%-69%) with >40 points. CONCLUSIONS: This risk score model predicts deep postoperative infection in patients with open tibial shaft fractures treated with intramedullary nails. The ability to accurately estimate deep infection risk at the time of presentation might aid patient expectation management and allow clinicians to focus infection prevention strategies on the high-risk subset of this population.


Assuntos
Fixação Intramedular de Fraturas , Fraturas Expostas , Fraturas da Tíbia , Ferimentos por Arma de Fogo , Humanos , Adulto , Infecção da Ferida Cirúrgica/epidemiologia , Infecção da Ferida Cirúrgica/prevenção & controle , Infecção da Ferida Cirúrgica/etiologia , Estudos Retrospectivos , Ferimentos por Arma de Fogo/complicações , Fraturas da Tíbia/cirurgia , Fraturas da Tíbia/complicações , Fixação Intramedular de Fraturas/efeitos adversos , Pinos Ortopédicos/efeitos adversos , Fatores de Risco , Fraturas Expostas/complicações , Fraturas Expostas/cirurgia , Resultado do Tratamento , Consolidação da Fratura
3.
Orthopedics ; 46(4): 198-204, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36853932

RESUMO

Fixation of humeral shaft fractures is frequently performed with large-fragment (4.5 mm) plates to accommodate immediate weight bearing. Use of small-fragment (3.5 mm) plates as an alternative carries theoretical benefits. We examined nonunion rates and postoperative radial nerve palsy (RNP) rates in a retrospective cohort of patients undergoing open reduction and internal fixation of humeral shaft fractures with 3.5-mm or 4.5-mm plates. Two hundred thirty-six patients with 241 humeral shaft fractures were included. Small 3.5-mm plates were used in 83% of the patients, and large 4.5-mm plates were used in 17% of the patients. Fifty-three percent were made weight bearing as tolerated following surgical fixation. There was a 7% incidence of nonunion and a 10% incidence of RNP in the 3.5-mm plate group. There was a 7% incidence of nonunion and a 15% incidence of RNP in the 4.5-mm plate group. No statistically significant relationship was shown between nonunion or RNP and plate size (P=.74 and P=.39). No relationship was shown between nonunion and postoperative weight-bearing status (P=.45). Subgroup analysis according to plate size additionally showed no association of nonunion with postoperative weight bearing in both the 4.5-mm (P=.55) and the 3.5-mm (P=.25) cohorts. Small-fragment and large-fragment plating of humeral shaft fractures resulted in comparable union and RNP rates, regardless of postoperative weight-bearing status. Our findings suggest that 3.5-mm plate fixation of humeral shaft fractures is a safe alternative to 4.5-mm plate fixation. [Orthopedics. 2023;46(4):198-204.].


Assuntos
Consolidação da Fratura , Fraturas do Úmero , Humanos , Estudos Retrospectivos , Fraturas do Úmero/cirurgia , Fixação Interna de Fraturas/efeitos adversos , Fixação Interna de Fraturas/métodos , Úmero , Placas Ósseas , Resultado do Tratamento
4.
J Orthop Trauma ; 36(10): 509-514, 2022 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-35412511

RESUMO

OBJECTIVES: Operative management of acetabular fractures is technically challenging, but there is little data regarding how surgeon experience affects outcomes. Previous efforts have focused only on reduction quality in a single surgeon series. We hypothesized that increasing surgeon experience would be associated with improved acetabular surgical outcomes in general. DESIGN: Retrospective cohort study. SETTING: Urban academic level-I trauma center. PATIENTS/PARTICIPANTS: Seven hundred ninety-five patients who underwent an open reduction internal fixation for an acetabular fracture. RESULTS: There was a significant association between surgeon experience and certain outcomes, specifically reoperation rate (16.9% overall), readmission rate (13.9% overall), and reduction quality. Deep infection rate (9.7% overall) and secondary displacement rate (3.7% overall) were not found to have a significant association with surgeon experience. For reoperation rate, the time until 50% peak performance was 2.4 years in practice. CONCLUSION: Surgeon experience had a significant association with reoperation rate, quality of reduction, and readmission rate after open reduction internal fixation of acetabular fractures. Other patient outcomes were not found to be associated with surgeon experience. LEVEL OF EVIDENCE: Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.


Assuntos
Acetábulo , Competência Clínica , Fixação Interna de Fraturas , Fraturas Ósseas , Redução Aberta , Acetábulo/lesões , Competência Clínica/estatística & dados numéricos , Fixação Interna de Fraturas/efeitos adversos , Fraturas Ósseas/cirurgia , Humanos , Redução Aberta/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , Estudos Retrospectivos , Cirurgiões , Resultado do Tratamento
5.
Injury ; 53(2): 590-595, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34802699

RESUMO

INTRODUCTION: Femoral neck fractures in the young patient present a unique challenge. Most surgeons managing these injuries prefer a fixed angle implant, however these devices are fraught with problems. A dynamic hip screw (DHS) is one such fixed angle device that risks malreduction through rotational torque during screw insertion. To avoid this risk some surgeons utilize a dynamic helical hip system (DHHS), however little is known about the complication profile of this device. We hypothesized that the complication rate between these two devices would be similar. PATIENTS AND METHODS: All patients presenting to a single tertiary referral center with a femoral neck fracture were identified from a prospectively collected trauma database over an 11-year period. Patients were included if they were less than 60 years of age, treated with a DHS or DHHS, and had at least 6 months of follow-up. Demographic data, injury characteristics, and post-operative complications were obtained through chart review. Standard statistical comparisons were made between groups. A total of 77 patients met inclusion criteria. RESULTS: Average age of patients was 38 years (range: 18-59) and 56 (73%) were male. The DHS was used in 37 (48%) patients and the DHHS was used in 40 (52%) patients. Demographic data including average age, gender, body mass index, and smoking status did not differ between the groups. There were 29 (39%) total complications of interest (femoral neck shortening >5 mm, non-union requiring osteotomy, conversion to THA, and osteonecrosis. There were 19 (51%) complications in the DHS group and 10 (25%) in the DHHS group (p = 0.01, risk difference 25%, 95% CI 7-43). Comparisons of the individual complications about the DHS and DHHS cohort did not reach statistical significance for non-union (8% vs 3%) or THA (16% vs 13%) (p = 0.33, p = 0.64, respectively) but a difference was detected in the rate of shortening (27% vs 10%; p = 0.05). CONCLUSION: This study demonstrates a high risk of complication when managing young femoral neck fractures in line with prior literature. The major complication rate of non-union requiring osteotomy or fixation failure resulting in THA was no different between the two groups, but the rate of shortening was greater the DHS group. This data suggests the DHHS may be a suitable device to manage the young femoral neck fracture and without increased risk of complication.


Assuntos
Fraturas do Colo Femoral , Fraturas do Quadril , Osteonecrose , Adolescente , Adulto , Parafusos Ósseos , Fraturas do Colo Femoral/cirurgia , Colo do Fêmur , Fixação Interna de Fraturas , Humanos , Lactente , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento , Adulto Jovem
6.
Injury ; 53(2): 523-528, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34649730

RESUMO

INTRODUCTION: The optimal treatment of elderly patients with an acetabular fracture is unknown. We conducted a prospective clinical trial to compare functional outcomes and reoperation rates in patients older than 60 years with acetabular fracture treated with open reduction and internal fixation (ORIF) alone versus ORIF plus concomitant total hip arthroplasty (ORIF + THA). Our hypothesis was that patients who had ORIF + THA would have better patient reported outcomes and lower reoperation rates postoperatively. METHODS: Inclusion criteria were patients older than 60 years with acetabular fracture plus at least one of three fracture characteristics: dome impaction, femoral head fracture, or posterior wall component. Eligible patients were operative candidates based on fracture displacement, ambulatory status, and physiological appropriateness. Patients received either ORIF alone or ORIF + THA (accomplished at same surgery through same incision). Outcome measurements included Western Ontario and McMaster Universities Osteoarthritis Index hip score, Short Form 36, Harris Hip Score, and Patient Satisfaction Questionnaire Short Form scores. Additionally, patients were monitored for any unplanned reoperation within 2 years. RESULTS: Forty-seven of 165 eligible patients with an average age of 70.7 years were included. The mean Harris Hip Score difference favored ORIF + THA (mean difference, 12.3, [95% confidence interval (CI), -0.3 to 24.9, p = 0.07]). No clinically important differences were detected in any other validated outcome score or patient satisfaction score 1 year after surgery. ORIF + THA decreased the absolute risk of reoperation by 28% (95% CI, 13% to 44%, p < 0.01). No postoperative hip dislocation occurred in either group. CONCLUSIONS: In patients older than 60 years with an operative displaced acetabular fracture with specific fracture features (dome impaction, femoral head fracture, or posterior wall component), treatment with ORIF + THA resulted in fewer reoperations than treatment with ORIF alone. No differences in patient satisfaction and other validated outcome measures were detected.


Assuntos
Artroplastia de Quadril , Fraturas Ósseas , Fraturas do Quadril , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Idoso , Fixação Interna de Fraturas , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/cirurgia , Fraturas do Quadril/cirurgia , Humanos , Redução Aberta , Estudos Prospectivos , Reoperação , Resultado do Tratamento
7.
J Orthop Trauma ; 35(12): 626-631, 2021 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-34797781

RESUMO

OBJECTIVES: To determine whether skin perfusion surrounding tibial plateau and pilon fractures is associated with the Tscherne classification for severity of soft tissue injury. The secondary aim was to determine if soft tissue perfusion improves from the time of injury to the time of definitive fracture fixation in fractures treated using a staged protocol. DESIGN: Prospective cohort study. SETTING: Academic trauma center. PATIENTS: Eight pilon fracture patients and 19 tibial plateau fracture patients who underwent open reduction internal fixation. MAIN OUTCOME MEASURES: Skin perfusion (fluorescence units) as measured by LA-ICGA. RESULTS: Six patients were classified as Tscherne grade 0, 9 as grade 1, 10 as grade 2, and 2 as grade 3. Perfusion decreased by 14 fluorescence units (95% confidence interval, -21 to -6; P < 0.01) with each increase in Tscherne grade. Sixteen patients underwent staged fixation with an external fixator (mean time to definitive fixation 14.1 days). The mean perfusion increased significantly at the time of definitive fixation by a mean of 13.9 fluorescence units (95% confidence interval 4.8-22.9; P = 0.01). CONCLUSIONS: LA-ICGA perfusion measures are associated with severity of soft tissue injury surrounding orthopaedic trauma fractures and appear to improve over time when fractures are stabilized in an external fixator. Further research is warranted to investigate whether objective perfusion measures are predictive of postoperative wound healing complications and whether this tool can be used to effectively guide timing of safe surgical fixation. LEVEL OF EVIDENCE: Prognostic Level II. See Instructions for Authors for a complete description of levels of evidence.


Assuntos
Fixação Interna de Fraturas , Fraturas da Tíbia , Angiografia , Fixadores Externos , Humanos , Lasers , Perfusão , Projetos Piloto , Estudos Prospectivos , Estudos Retrospectivos , Fraturas da Tíbia/diagnóstico por imagem , Fraturas da Tíbia/cirurgia , Resultado do Tratamento
8.
Injury ; 52(7): 1944-1950, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33867150

RESUMO

INTRODUCTION: Tibial plateau fractures are a heterogenous group of injuries with a variable amount of articular injury and are commonly associated with lateral sided articular impaction. Previous work has focused on describing the morphology of tibial plateau fractures, but has neglected description of medial sided articular impaction. The aim of this investigation was to assess the morphology of medial sided articular impaction in tibial plateau fractures, with specific attention directed toward the frequency, location, size, and associated fracture patterns. METHODS: Skeletally mature patients presenting to a Level I trauma center from 2008-2018 with a tibial plateau fracture (AO/OTA 41B-C) were identified retrospectively. Fractures were classified by AO/OTA and Schatzker type. Radiographs and computed tomography (CT) scans were reviewed to identify and localize medial sided articular impaction. The location and surface area of impaction was characterized by creating frequency diagram heat maps from axial CT scans. Descriptive statistics were performed using standard measures. RESULTS: Of the 1032 tibial plateau fractures included, 82 (7.9%) were noted to have medial sided articular impaction. Rate of impaction varied by fracture type (p = 0.03): Schatzker II, 2% (7 of 381); Schatzker IV, 21% (19 of 96); and Schatzker VI, 11% (56 of 524). Average total surface area of impaction was 9% of the total and 19% of the medial plateau area. Area of impaction varied by fracture type (p = 0.004): Schatzker II, 6% (95% confidence interval [CI], 4%-7%); Schatzker IV, 11% (95% CI, 9%-13%), and Schatzker VI, 9% (95% CI, 7%-11%). The area of impaction occurred primarily along the lateral aspect of the medial plateau in Schatzker II fractures, in the anteromedial quadrant of Schatzker IV fractures, and was evenly distributed across the medial plateau in Schatzker VI fractures. CONCLUSIONS: Surgeons should be aware that medial articular impaction is present in approximately 8% of tibial plateau fractures. Schatzker IV fractures are most likely to have medial impaction and a larger proportion of the joint surface involved in these injuries.


Assuntos
Fraturas da Tíbia , Humanos , Radiografia , Estudos Retrospectivos , Fraturas da Tíbia/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Centros de Traumatologia
9.
J Orthop Trauma ; 35(5): 239-244, 2021 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-32956208

RESUMO

OBJECTIVES: To assess the reliability of the current computed tomography (CT)-based technique for determining femoral anteversion and quantify the prevalence and magnitude of side-to-side differences. DESIGN: Cross-sectional cohort study. SETTING: Academic trauma center. PATIENTS: We reviewed CT scans from 120 patients with bilateral full-length axial cuts of both femurs. Two hundred forty femurs with no fractures or other identifying features in their femora were included. Ten unique data sets were created to measure anteversion of the left and right sides. MAIN OUTCOME MEASUREMENTS: Intraobserver and interobserver reliability were calculated using intraclass correlation coefficients (ICCs) and pooled absolute differences. The mean absolute difference between the sides was determined using a fixed-effects model. RESULTS: Interobserver reliability was high (ICC: 0.85, 95% confidence interval [CI]: 0.83-0.88). The pooled mean absolute magnitude of variation between reviewers was small at 1.6 degrees (95% CI: 1.4-1.8 degrees) per scan. The intraobserver reproducibility was high (ICC: 0.91, 95% CI: 0.88-0.93) with a mean error of 2.7 degrees (95% CI: 2.2-3.1 degrees) per repeat viewing of the same scan by the same person. The magnitude of side-to-side variation was 2.0 degrees (95% CI: 1.5-2.6 degrees). Twenty-one subjects (18%, 95% CI: 12%-25%) had a mean side-to-side calculated femoral anteversion difference of ≥10 degrees, whereas 6 (5%, 95% CI: 2-10) subjects had a calculated mean side-to-side difference of ≥15 degrees. CONCLUSIONS: CT based femoral anteversion measurement techniques demonstrate good precision. Only 1 in 20 patients had side-to-side differences of 15 degrees or more.


Assuntos
Fêmur , Tomografia Computadorizada por Raios X , Estudos Transversais , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Humanos , Reprodutibilidade dos Testes , Rotação
10.
J Orthop Trauma ; 35(2): 100-105, 2021 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-32658018

RESUMO

OBJECTIVES: To determine the association between displaced femoral shaft bone fragments ("spikes") seen on radiographs after intramedullary nail insertion and the need for future motion surgery. DESIGN: Retrospective case-control study. SETTING: Academic trauma center. PATIENTS: We included patients with femoral shaft fractures treated with intramedullary nail insertion. Case patients (n = 22) had developed knee stiffness treated with motion surgery. The control group was a randomly selected sample (1:3 ratio). MAIN OUTCOME MEASURES: Motion surgery to address knee stiffness. We defined a "spike distance ratio" and "spike area ratio" from initial postoperative anteroposterior and lateral radiographs. Multivariable logistic regression determined the effect of spike distance and area ratios on the likelihood of need for motion surgery, controlling for polytraumatic injuries and bilateral fractures. RESULTS: The case group had a median femoral spike distance ratio of 1.9 [interquartile range (IQR), 1.6-2.5] compared with 1.5 (IQR, 1.2-1.8) in the control group. An increased femoral spike distance ratio was associated with increased odds of motion surgery (P < 0.01). A femoral spike distance >2 times the femoral radius had 32 times the odds (95% confidence interval, 2-752) of motion surgery compared with patients with distance ratios <1.25. Median femoral spike area ratios were similar between the case (0.2; IQR, 0.1-0.5) and control (0.2; IQR, 0.0-0.5) groups and were not associated with increased odds of motion surgery (P = 0.34). CONCLUSIONS: A larger spike distance ratio is associated with increased odds of subsequent motion surgery. LEVEL OF EVIDENCE: Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.


Assuntos
Fraturas do Fêmur , Fixação Intramedular de Fraturas , Pinos Ortopédicos , Estudos de Casos e Controles , Fraturas do Fêmur/diagnóstico por imagem , Fraturas do Fêmur/cirurgia , Fixação Intramedular de Fraturas/efeitos adversos , Humanos , Estudos Retrospectivos , Resultado do Tratamento
11.
J Orthop Trauma ; 34(7): e256-e260, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32555041

RESUMO

We describe the novel quantitative lesser trochanter profile (QLTP) technique to determine the magnitude and direction of femoral malrotation and to compare its performance with the cortical step sign technique. For this assessment, 9 orthopaedic surgeons estimated the magnitude and direction of femoral malrotation with each technique in 198 anteroposterior view images of the proximal cadaveric femur and osteotomy sites. Based on the results, the main benefit of the QLTP technique over the cortical step sign technique is the ability to determine the direction of femoral malrotation. The QLTP technique was also more accurate in measuring malrotation and had less error. However, the QLTP technique requires additional imaging, and the mean difference in error between the 2 techniques might not be clinically meaningful.


Assuntos
Fraturas do Fêmur , Fixação Intramedular de Fraturas , Fraturas do Fêmur/diagnóstico por imagem , Fraturas do Fêmur/cirurgia , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Humanos , Osteotomia
12.
Injury ; 51(7): 1662-1668, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32434717

RESUMO

INTRODUCTION: We assessed the outcome and safety of posterior plating of distal tibial fractures. METHODS: We conducted a retrospective case series at a Level I trauma center. Seventy-four consecutive patients with distal tibial fractures treated with anatomically contoured 3.5-mm T-shaped locking compression plate using a posterolateral approach from January 2008 through April 2018 were included in the study. The mean patient age was 48 years (range, 18-87 years). Fifty-nine percent of the patients were male patients, 47% of the fractures were open fractures; and 27% of the patients had multiple traumatic injuries. Eleven fractures were AO/OTA type 42, 22 were type 43A, and 41 were type 43C. Sixty-two (84%) patients were treated with initial spanning external fixation (median time, 23 days) and staged open reduction and internal fixation. The main outcome measure was unplanned reoperation to address implant failure, nonunion, deep surgical site infection, or symptomatic implant. RESULTS: Overall risk of unplanned reoperation was 15% (11 of 74 patients, 95% confidence interval, 9%-25%). Four (5%) reoperations were for nonunion, three (4%) were for surgical site infection, two (3%) were for infected nonunion, and two (3%) were for implant prominence. Loss of alignment >10 degrees occurred in one patient who underwent unplanned reoperation for nonunion. No plate breakage occurred. Median time to reoperation was 221 days (range, 22-436 days). Only one other complication was noted: wound dehiscence associated with the posterolateral approach, which was treated with irrigation and débridement and a 6-week regimen of oral antibiotics. CONCLUSIONS: Use of a posterolateral approach with a pre-contoured locking compression T-plate for the treatment of distal tibial fractures led to reasonable outcomes with an acceptable risk of unplanned reoperation, even with a high proportion of open fractures commonly staged with external fixation.


Assuntos
Placas Ósseas , Fixação Interna de Fraturas/métodos , Fraturas Expostas/cirurgia , Infecção da Ferida Cirúrgica/prevenção & controle , Fraturas da Tíbia/cirurgia , Adulto , Traumatismos do Tornozelo/diagnóstico por imagem , Traumatismos do Tornozelo/cirurgia , Fixadores Externos , Feminino , Fixação Interna de Fraturas/instrumentação , Consolidação da Fratura , Fraturas Expostas/diagnóstico por imagem , Fraturas não Consolidadas/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia , Amplitude de Movimento Articular , Reoperação , Estudos Retrospectivos , Fraturas da Tíbia/diagnóstico por imagem
13.
J Orthop Trauma ; 34(12): e454-e459, 2020 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-32379226

RESUMO

SUMMARY: Acetabular fractures may not always be amenable to classic clamp-assisted reductions and interfragmentary lag screw fixation. The routine clamp-assisted reductions with limited osseous territory availability can inhibit typical 3.5-mm reconstruction plate application. Provisional minifragment plate fixation of these fracture patterns with subsequent clamp removal allows for definitive plate application. The provisional minifragment plates may also be retained to theoretically augment fixation. The authors present a step-by-step technique and clinical series of 57 patients demonstrating provisional minifragment fixation of elementary (n = 8) and associated (n = 49) acetabular fractures.


Assuntos
Fraturas Ósseas , Fraturas do Quadril , Acetábulo/cirurgia , Placas Ósseas , Parafusos Ósseos , Fixação Interna de Fraturas , Fraturas Ósseas/cirurgia , Fraturas do Quadril/diagnóstico por imagem , Fraturas do Quadril/cirurgia , Humanos
14.
Injury ; 51(3): 699-704, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32037004

RESUMO

In polytrauma patients with unstable pelvic ring injuries, pelvic binders interfere with femoral arterial access and are frequently removed for emergent endovascular and abdominal procedures. The 'trochanteric C-clamp' (T-clamp) is a novel technique described for rapid stabilization of the pelvis without fluoroscopic imaging, while ensuring adequate access to the groin. This case series reports the feasibility and safety following T-clamp application for unstable pelvic ring injuries in patients requiring simultaneous endovascular intervention. Between May 2018 - May 2019, seventeen patients with unstable pelvic ring injuries were treated with a T-clamp in conjunction with other emergent endovascular or intra-abdominal procedures. Nine presented with unstable APC injuries, seven with unstable LC injuries and one with a vertical shear pattern. Complications related to the T-clamp were prospectively collected. Following T-clamp application, there were two cases of intraoperative over-reduction, one of which required exchange for an anterior external fixator. This was the result of a concomitant acetabulum fracture leading to iatrogenic acetabular protrusion secondary to the T-clamp. Twelve cases maintained the T-clamp fixation postoperatively ranging from 1-3 days. One postoperative loss of reduction was noted and required exchange for anterior external fixator. In hemodynamically unstable patients who require emergent endovascular procedures, such as pelvic angiography and REBOA, T-clamp application offers a reasonably safe and effective method for expeditious stabilization of the pelvis while allowing unimpeded access to the abdomen, groin and pelvis. Caution should also be applied in patients with concomitant acetabulum fracture for risk of malreduction. Additionally, its prolonged postoperative use should be limited to patients who are not immediately suitable for fixation of the pelvis.


Assuntos
Fixadores Externos , Fraturas Ósseas/cirurgia , Traumatismo Múltiplo/cirurgia , Ossos Pélvicos/lesões , Instrumentos Cirúrgicos , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Adolescente , Adulto , Idoso , Feminino , Fraturas Ósseas/diagnóstico por imagem , Hemodinâmica , Humanos , Masculino , Maryland , Pessoa de Meia-Idade , Traumatismo Múltiplo/diagnóstico por imagem , Ossos Pélvicos/diagnóstico por imagem , Radiografia , Estudos Retrospectivos , Centros de Traumatologia , Adulto Jovem
15.
Orthopedics ; 43(1): e43-e46, 2020 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-31770449

RESUMO

This study sought to determine (1) whether surgeons can accurately predict functional outcomes of operative fixation of pilon fractures based on injury and initial postoperative radiographs, (2) whether the surgeon's level of experience is associated with the ability to successfully predict outcome, and (3) the association between patients' demographic and clinical characteristics and surgeons' prediction scores. A blinded, randomized provider survey was conducted at a level I trauma center. Seven fellowship-trained orthopedic traumatologists and 4 orthopedic trauma fellows who were blinded to outcome reviewed data regarding 95 pilon fractures in random order. Injury ankle radiographs, initial postoperative fixation radiographs, and brief patient histories were assessed. Midterm follow-up functional outcome scores obtained a mean 4.9 years after surgery were available for all patients. Main outcome measures were Pearson correlation coefficient-assessed functional outcomes and surgeon-predicted outcomes. A mixed-effect model determined the association between patients' characteristics and surgeons' prediction scores. Minimal positive correlation was observed between functional outcomes and prediction scores. No difference was noted between the attending and fellow groups in prediction ability. When surgeons' prediction confidence level was greater than 1 SD above the mean confidence level, correlation between functional outcome and prediction improved, although poor correlation was still observed. AO/OTA type 43C fractures, high-energy mechanisms, and older patient age were characteristics associated with lower prediction scores. Surgeons had poor ability to predict functional outcomes of patients with pilon fractures based on injury and initial postoperative radiographs, and level of experience was not associated with ability to predict outcome. [Orthopedics. 2020; 43(1): e43-e46.].


Assuntos
Fraturas do Tornozelo/cirurgia , Procedimentos Ortopédicos , Fraturas da Tíbia/cirurgia , Adulto , Idoso , Fraturas do Tornozelo/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia , Fraturas da Tíbia/diagnóstico por imagem , Resultado do Tratamento , Adulto Jovem
16.
J Am Acad Orthop Surg ; 28(2): 66-73, 2020 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-31884503

RESUMO

Intramedullary fixation of proximal tibia fractures remains a challenging surgical technique, with malalignment reported as high as 84%. The pull from the extensor mechanism, the hamstring and iliotibial band, in addition to the lack of endosteal fit from the nail, has made surgical fixation of these fractures difficult. Commonly held principles to reduce angular deformity include ensuring adequate imaging, obtaining an optimal start and trajectory for the implant, and obtaining and maintaining a reduction throughout the duration of the procedure. Some adjunctive techniques to assist in the application of these principles include use of a semiextended technique, clamping, blocking screws/wires, and unicortical plates. Understanding the challenges involved in intramedullary nailing of proximal tibia fractures and considering a wide array of techniques in the orthopaedic surgeon's armamentarium to combat these challenges is important.


Assuntos
Fixação Intramedular de Fraturas/métodos , Fixadores Internos , Fraturas da Tíbia/cirurgia , Fixação Intramedular de Fraturas/instrumentação , Humanos
17.
J Orthop Trauma ; 33(11): e427-e432, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31634288

RESUMO

OBJECTIVES: As hospitals seek to control variable expenses, orthopaedic surgeons have come under scrutiny because of relatively high implant costs. We aimed to determine whether feedback to surgeons regarding implant costs results in changes in implant selection. METHODS: This study was undertaken at a statewide trauma referral center and included 6 fellowship-trained orthopaedic trauma surgeons. A previously implemented implant stewardship program at our institution using a "red-yellow-green" (RYG) implant selection tool classifies 7 commonly used trauma implant constructs based on cost and categorizes each implant as red (used for patient-specific requirements, most expensive), yellow (midrange), and green (preferred vendor, least expensive). The constructs included were femoral intramedullary nail, tibial intramedullary nail, long and short cephalomedullary nails, distal femoral plate, proximal tibial plate, and lower-limb external fixator. Baseline implant usage from the previous year was obtained and provided to each surgeon. Each surgeon received a monthly feedback report containing individual implant utilization and overall ranking. RESULTS: The overall RYG score increased from 68.7 to 79.1 of 100 (P < 0.001). Three of the 7 implants (tibial and femoral nails and lower-limb external fixation) had significant increases in their RYG scores; implant selections for the other 4 implants were not significantly altered. A decrease of 1.8% (95% confidence interval, 0.4-3.2, P = 0.01) was noted in overall implant costs over the study period. CONCLUSION: Our intervention resulted in changes in surgeons' implant selections and cost savings. However, surgeons were unwilling to change certain implants despite their being more expensive.


Assuntos
Pinos Ortopédicos/estatística & dados numéricos , Placas Ósseas/estatística & dados numéricos , Análise Custo-Benefício , Fixação Interna de Fraturas/instrumentação , Fixação Intramedular de Fraturas/instrumentação , Fraturas Ósseas/cirurgia , Pinos Ortopédicos/economia , Placas Ósseas/economia , Redução de Custos , Feminino , Fixação Interna de Fraturas/métodos , Fixação Intramedular de Fraturas/métodos , Fraturas Ósseas/diagnóstico , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Análise e Desempenho de Tarefas , Centros de Traumatologia , Estados Unidos
18.
Radiol Clin North Am ; 57(4): 823-841, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31076035

RESUMO

Acetabular fractures are encountered by radiologists in a wide spectrum of practice settings. The radiologist's value in the acute and long-term management of acetabular fractures is augmented by familiarity with systematic computed tomography-based algorithms that streamline and simplify Judet-Letournel fracture typing, together with an appreciation of the role of imaging in initial triage, operative decision making, postoperative assessment, prognostication, and evaluation of complications. The steep increase in incidence of acetabular fractures in the elderly over the past several decades places special emphasis on familiarity with geriatric fracture patterns.


Assuntos
Acetábulo/diagnóstico por imagem , Acetábulo/lesões , Fraturas Ósseas/diagnóstico por imagem , Fraturas do Quadril/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Humanos
19.
Injury ; 49(11): 2075-2082, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30172349

RESUMO

INTRODUCTION: Intramedullary (IM) nail fixation is a common operative treatment, yet concerns regarding the frequency of complications, such as nonunion, remain. Treatment of tibial shaft fractures remains a challenge, and little evidence of prognostic factors that increase risk of nonunion is available. The aim of this study was to develop a predictive model of tibial shaft fracture nonunion 6 weeks after reamed intramedullary (IM) nail fixation based on commonly collected clinical variables and the radiographic union score for tibial fractures (RUST). METHODS: A retrospective case-control study was conducted. All tibial shaft fractures treated at our level I trauma center from 2007 to 2014 were retrospectively reviewed. Only patients with follow-up until fracture healing or secondary operation for nonunion were included. Fracture gaps ≥3 mm were excluded. A total of 323 patients were included for study. RESULTS: Infection within 6 weeks of operation, standard RUST, and the Nonunion Risk Determination (NURD) score had statistically significant associations with nonunion (odds ratio > or < 1.0; p < 0.01). The NURD score was increasingly predictive of nonunion with decreasing RUST. All patients in the high RUST group (RUST ≥ 10), achieved union regardless of NURD score. In the medium RUST group (RUST 6-9), 25% of patients with a NURD score ≥7 experienced nonunion. In the low RUST group (RUST <6 or infection within 6 weeks), 69% of patients with a NURD score ≥7 experienced nonunion. CONCLUSION: Three variables predicted nonunion. Based on these variables, we created a clinical prediction tool of nonunion that could aid in clinical decision making and discussing prognosis with patients.


Assuntos
Fixação Intramedular de Fraturas/efeitos adversos , Consolidação da Fratura/fisiologia , Fraturas não Consolidadas/fisiopatologia , Complicações Pós-Operatórias/fisiopatologia , Fraturas da Tíbia/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Feminino , Fixação Intramedular de Fraturas/instrumentação , Fraturas não Consolidadas/diagnóstico por imagem , Fraturas não Consolidadas/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/cirurgia , Valor Preditivo dos Testes , Estudos Retrospectivos , Fatores de Risco , Fraturas da Tíbia/diagnóstico por imagem , Fraturas da Tíbia/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
20.
J Orthop Trauma ; 32(7): e251-e257, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29916991

RESUMO

OBJECTIVES: To identify the risk factors for early reoperation after operative fixation of acetabular fractures. DESIGN: Retrospective evaluation. SETTING: Level I Trauma Center. PATIENTS: Seven hundred ninety-one patients with displaced acetabular fractures treated with open reduction and internal fixation (ORIF) from 2006 to 2015. Average follow-up was 52 weeks. MAIN OUTCOME MEASURES: Early reoperation after acetabular ORIF, defined as secondary procedure for infection or revision within 3 years of initial operation. RESULTS: Fifty-six (7%) patients underwent irrigation and debridement for infection and wound complications. Four associated risk factors identified were length of stay in the intensive care unit, pelvic embolization, operative time, and time delay between injury and surgical fixation. Sixty-two (8%) patients underwent early revision, including 45 conversions to total hip arthroplasty, 10 revision ORIF, 6 fixation device removals because of concern for joint penetration (2 acutely and 4 > 6 months after surgery), and 1 stabilization procedure. Three risk factors associated with early revision were hip dislocation, articular comminution, and concomitant femoral head or neck injury. Combined injuries to the pelvic ring and acetabulum, fracture pattern, marginal impaction, and body mass index had no significant effect on early revision surgery. CONCLUSIONS: Risk factors for early reoperation after operative fixation of acetabular fractures differed based on the reason for return to the operating room. Infection was more likely to occur in patients who had prolonged stays in the intensive care unit, had prolonged operative times, were embolized, or experienced delay in time to fixation. Revision was more likely with hip dislocation, articular comminution, femoral head or neck fracture, and advancing age. LEVEL OF EVIDENCE: Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.


Assuntos
Acetábulo/lesões , Fratura-Luxação/cirurgia , Fraturas Ósseas/cirurgia , Redução Aberta/efeitos adversos , Reoperação/métodos , Infecção da Ferida Cirúrgica/cirurgia , Acetábulo/cirurgia , Adulto , Idoso , Estudos de Coortes , Feminino , Seguimentos , Fratura-Luxação/diagnóstico por imagem , Consolidação da Fratura/fisiologia , Fraturas Ósseas/diagnóstico por imagem , Humanos , Escala de Gravidade do Ferimento , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Redução Aberta/métodos , Análise de Regressão , Estudos Retrospectivos , Infecção da Ferida Cirúrgica/diagnóstico , Fatores de Tempo , Centros de Traumatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...